BRKR 3VA41 2P 125A 65KA FTFM LD LUG

Manufacturer: SiemensItem #: SIE12363010

BRKR 3VA41 2P 125A 65KA Molded Case Circuit Breaker The Siemens 3VA41 molded case circuit breaker is designed for reliable electrical protection in industrial and commercial applications. It offers thermal-magnetic trip unit protection with a high breaking capacity suitable for use by electrical distributors, switchgear suppliers, and in lighting solutions requiring robust wire and cable protection. This 2-pole device ensures system protection with a permanently set overload and short-circuit trip unit, ideal for line protection in HVAC and refrigeration circuits. Specifications Manufacturer: Siemens Manufacturer Part #: 3VA4112-6ED24-0AA0 Frame Size: 3VA41 UL Frame 125 Rated Current: 125 A Number of Poles: 2 Breaking Capacity (UL 489): 65 kA at 480 V, 25 kA at 600Y/347 V, 100 kA at 240 V Trip Unit: Thermal-Magnetic TM210 with fixed Ir and Ii Overload Protection: 125 A permanently set Short-Circuit Protection: Ii = 10 x In Operating Voltage (AC Rated): 415 V Power Loss: Maximum 19.4 W, 9.7 W per pole at rated current Mechanical Service Life: 15,000 operating cycles (typical) Electrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V Dimensions (W x H x D): 5.31 in x 2.28 in x 6.61 in Conductor Connection: Circular conductor connection on output side, low tab on infeed side Connection Surface Finish: Tin plated Type of Connectable Conductors: 1 x (8 AWG - 3/0) stranded round conductors Protection Class (Front): IP40 Ambient Operating Temperature Range: -25 °C to 70 °C Weight: 1.31 lbs (0.514 kg) Features Thermal-magnetic trip unit (TM210) providing reliable overload and short-circuit protection High breaking capacity class H suitable for demanding electrical distribution systems Special feature: lugs installed on load side only for simplified wiring Designed for HVAC and refrigeration circuit protection (HACR Type) Compact size for space-efficient panel designs Durable mechanical and electrical endurance for long service life UL Listed and compliant with UL 489 standards Downloads & Links How do I compare devices in TIA-Selection-Tool? How do I use the data matrix code correctly? Short-circuit current rating (SCCR) in industrial control panels? 3D Image Technical data sheet What is the significance of the IP protection class?

Specifications

Shipping & Support

Product image 1
Request a Quote

Volume or contract pricing? Call (845) 9-ALYJOE (845) 925-9563.

From $1,726.32
BRKR 3VA41 2P 125A 65KA FTFM LD LUG—
$1,726.32
BRKR 3VA41 2P 125A 65KA FTFM LD LUG | Alyjoe Group