BRKR 3VA41 2P 25A 65KA FTFM LD LUG

Manufacturer: SiemensItem #: SIE12362609

BRKR 3VA41 2P 25A 65KA FTFM LD LUG Molded Case Circuit Breaker The Siemens 3VA41 molded case circuit breaker is designed for reliable system protection in electrical distribution. This 2-pole, 25A breaker features a thermal-magnetic TM210 trip unit with fixed overload and short-circuit settings, suitable for use by electrical distributors and switchgear suppliers requiring high breaking capacity and durable overload protection. It is ideal for applications in lighting solutions, wire and cable systems, and general electrical protection up to 415 V AC. Specifications Manufacturer: Siemens Manufacturer Part #: 3VA4125-6ED24-0AA0 Frame Size: 3VA41 (Frame 125) Number of Poles: 2 Rated Current: 25 A Breaking Capacity (UL 489): 65 kA at 480 V, 25 kA at 600Y/347 V Trip Unit: TM210 thermal-magnetic, fixed Ir and Ii Operating Voltage (Rated): 415 V AC Switching Capacity Class: H Dimensions (W x H x D): 2 in x 5.09 in x 2.96 in (50.8 mm x 129.4 mm x 75.1 mm) Connection Type: Load side lugs installed only, low tab input, circular conductor output Type of Connectable Conductors: 1 x (14 AWG - 8 AWG) stranded Power Loss: Maximum 5.4 W (2.7 W per pole at rated current) Mechanical Service Life: 15,000 operating cycles Electrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V Protection Class (Front): IP40 Ambient Operating Temperature: -25 °C to 70 °C Product Weight: 1.31 lbs (0.514 kg) Features Thermal-magnetic TM210 trip unit with fixed overload and short-circuit protection High breaking capacity suitable for demanding electrical distribution environments UL listed for HACR (Heating, Air Conditioning, and Refrigeration) and HID (High-Intensity Discharge) applications Load side lug installation for simplified wiring No auxiliary or undervoltage release components, reducing complexity Durable construction with tin-plated connections to ensure reliable electrical contact Compact size optimized for panel and switchgear integration Downloads & Links How do I use the data matrix code correctly? Short-circuit current rating (SCCR) in industrial control panels? Technical data sheet 3D Image What is the significance of the IP protection class? How do I compare devices in TIA-Selection-Tool?

Specifications

Shipping & Support

Product image 1
Request a Quote

Volume or contract pricing? Call (845) 9-ALYJOE (845) 925-9563.

From $821.18
BRKR 3VA41 2P 25A 65KA FTFM LD LUG—
$821.18
BRKR 3VA41 2P 25A 65KA FTFM LD LUG | Alyjoe Group